Zebra 220Xi4 Error Code Out Of Memory Storing Format


Possible Cause

There is not enough memory to perform the function specified on the second line of the error message.

Solution

1.Free up some of the printer’s memory by adjusting the label format or printer parameters. One way to free up memory is to adjust the print width to the actual width of the label instead of leaving the print width set to the default.

2. Ensure that the device, such as FLASH memory or PCMCIA card, is installed and not write protected.

3. Ensure that the data is not directed to a device that is not installed or is unavailable.